GSO ASTM F1862/F1862M:2022

Gulf Standard   Current Edition
· Approved on 12 May 2022 ·

Standard Test Method for Resistance of Medical Face Masks to Penetration by Synthetic Blood (Horizontal Projection of Fixed Volume at a Known Velocity)

GSO ASTM F1862/F1862M:2022 Files

GSO ASTM F1862/F1862M:2022 Scope

1.1 This test method is used to evaluate the resistance of medical face masks to penetration by the impact of a small volume (~2 mL) of a high-velocity stream of synthetic blood. Medical face mask pass/fail determinations are based on visual detection of synthetic blood penetration. 1.2 This test method does not apply to all forms or conditions of blood-borne pathogen exposure. Users of the test method must review modes for face exposure and assess the appropriateness of this test method for their specific application. 1.3 This test method primarily addresses the performance of materials or certain material constructions used in medical face masks. This test method does not address the performance of the medical face mask’s design, construction, or interfaces or other factors with the potential to affect the overall protection offered by the medical face mask and its operation (such as filtration efficiency and pressure drop). Procedures for measuring these properties are contained in Test Method F2101 and MIL-M-36954C. 1.4 This test method does not address breathability of the medical face mask materials or any other properties affecting the ease of breathing through the medical face mask. This test method evaluates medical face masks as an item of protective clothing. This test method does not evaluate the performance of medical face masks for airborne exposure pathways or in the prevention of the penetration of aerosolized body fluids deposited on the medical face mask. 1.5 The values stated in SI units or inch-pound units are to be regarded separately as standard. The pressure values stated in each system are not exact equivalents. However, as the corresponding velocities are within 1 % of each other, (see X1.4.2), reporting of the results in either units is permitted. 1.6 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

Best Sellers From Health Sector

BH GSO 1943:2022
GSO 1943:2021 
Bahraini Technical Regulation
Cosmetic Products – Safety Requirements of Cosmetics and Personal Care Products
GSO 1943:2021
 
Gulf Technical Regulation
Cosmetic Products – Safety Requirements of Cosmetics and Personal Care Products
GSO 2017:2023
 
Gulf Standard
Personal Care and Baby Wet Wipes
BH GSO 2017:2023
GSO 2017:2023 
Bahraini Standard
Personal Care and Baby Wet Wipes

Recently Published from Health Sector

GSO ISO 11978:2024
ISO 11978:2017 
Gulf Standard
Ophthalmic optics — Contact lenses and contact lens care products — Labelling
GSO ISO 16256:2024
ISO 16256:2021 
Gulf Standard
Clinical laboratory testing and in vitro diagnostic test systems — Broth micro-dilution reference method for testing the in vitro activity of antimicrobial agents against yeast fungi involved in infectious diseases
GSO ISO 14708-3:2024
ISO 14708-3:2017 
Gulf Standard
Implants for surgery — Active implantable medical devices — Part 3: Implantable neurostimulators
GSO ISO 11608-6:2024
ISO 11608-6:2022 
Gulf Standard
Needle-based injection systems for medical use — Requirements and test methods — Part 6: On-body delivery systems