GSO ISO/ASTM 51940:2017 Scope

1.1 This guide outlines dosimetric procedures to be followed for the radiation-induced reproductive sterilization of live insects for use in pest management programs. The primary use of such insects is in the Sterile Insect Technique, where large numbers of reproductively sterile insects are released into the field to mate with and thus control pest populations of the same species. A secondary use of sterile insects is as benign hosts for rearing insect parasitoids. The procedures outlined in this guide will help ensure that insects processed with ionizing radiation from gamma, electron, or X-ray sources receive absorbed doses within a predetermined range. Information on effective dose ranges for specific applications of insect sterilization, or on methodology for determining effective dose ranges, is not within the scope of this guide. NOTE 1—Dosimetry is only one component of a total quality assurance program to ensure that irradiated insects are adequately sterilized and fully competitive or otherwise suitable for their intended purpose. 1.2 This guide provides information on dosimetry for the irradiation of insects for these types of irradiators: selfcontained dry-storage 137Cs or 60Co irradiators, self-contained low-energy X-ray irradiators (maximum processing energies from 150 to 300 keV), large-scale gamma irradiators, and electron accelerators (electron and X-ray modes). NOTE 2—Additional, detailed information on dosimetric procedures to be followed in installation qualification, operational qualification, performance qualification, and routine product processing can be found in ISO/ASTM Practices 51608 (X-ray [bremsstrahlung] facilities processing at energies over 300 keV), 51649 (electron beam facilities), 51702 (large-scale gamma facilities), and 52116 (self-contained dry-storage gamma facilities), and in Ref (1) (self-contained X-ray facilities). 1.3 The absorbed dose for insect sterilization is typically within the range of 20 to 600 Gy. 1.4 This guide refers, throughout the text, specifically to reproductive sterilization of insects. It is equally applicable to radiation sterilization of invertebrates from other taxa (for example, Acarina, Gastropoda) and to irradiation of live insects or other invertebrates for other purposes (for example, inducing mutations), provided the absorbed dose is within the range specified in 1.3. 1.5 This guide also covers the use of radiation-sensitive indicators for the visual and qualitative indication that the insects have been irradiated. 1.6 This document is one of a set of standards that provides recommendations for properly implementing and utilizing dosimetry in radiation processing and describes a means of achieving compliance with the requirements of ASTM Practice E2628. It is intended to be read in conjunction with ASTM E2628. 1.7 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use

Best Sellers From Metrology Sector

GSO OIML R87:2021
OIML R87:2016 
Gulf Standard
Quantity of product in prepackages
BH GSO OIML R87:2022
GSO OIML R87:2021 
Bahraini Standard
Quantity of product in prepackages
GSO OIML R79:2021
OIML R79:2015 
Gulf Standard
Labeling requirements for prepackages
BH GSO OIML R79:2022
GSO OIML R79:2021 
Bahraini Standard
Labeling requirements for prepackages

Recently Published from Metrology Sector

BH GSO IEC 62053-41:2023
GSO IEC 62053-41:2023 
Bahraini Standard
Electricity metering equipment - Particular requirements - Part 41: Static meters for DC energy (classes 0,5 and 1)
BH GSO ISO 16610-20:2023
GSO ISO 16610-20:2023 
Bahraini Standard
Geometrical product specifications (GPS) — Filtration — Part 20: Linear profile filters: Basic concepts
BH GSO OIML D31:2023
GSO OIML D31:2023 
Bahraini Standard
General requirements for software controlled measuring instruments
BH GSO OIML R 149-1:2023
GSO OIML R 149-1:2023 
Bahraini Standard
Non-invasive automated sphygmomanometers Part 1: Metrological and technical requirements