GSO ISO 30011:2017

Gulf Standard   Current Edition
· Approved on 03 October 2017 ·

Workplace air -- Determination of metals and metalloids in airborne particulate matter by inductively coupled plasma mass spectrometry

GSO ISO 30011:2017 Files

English 34 Pages
Current Edition Reference Language
65.04 BHD

GSO ISO 30011:2017 Scope

This International Standard specifies a procedure for the use of quadrupole inductively coupled plasma mass spectrometry (ICP-MS) for analysing test solutions prepared from samples of airborne particulate matter collected as specified in ISO 15202-1. Method development, performance checks, and a routine analysis method are specified. Test solutions for analysis by this International Standard are prepared as specified in ISO 15202-2. This International Standard is applicable to the assessment of workplace exposure to metals and metalloids for comparison with limit values (see e.g. EN 689[10], ASTM E1370[8]). The following is a non-exclusive list of metals and metalloids for which limit values have been set (see Reference [15]) and for which one or more of the sample preparation methods specified in ISO 15202-2 and the analytical procedure described in this International Standard are applicable. However, there is no information available on the effectiveness of any of these sample preparation methods for those elements listed in italics. aluminium caesium lead platinum tungsten antimony chromium lithium potassium uranium arsenic cobalt magnesium rhodium vanadium barium copper manganese selenium yttrium beryllium gallium mercury silver zinc bismuth germanium molybdenum sodium zirconium boron hafnium nickel tellurium cadmium indium niobium thallium calcium iron phosphorus tin This International Standard is not applicable to determination of elemental mercury, since mercury vapour is not collected using the sampling method specified in ISO 15202-1. The procedure is suitable for assessment of exposure against the long-term exposure limits for most of the metals and metalloids listed above when sampling at a typical flow rate of 2 l min−1 for sampling times in the range 0,5 h to 8 h and for assessment of exposure against the short-term exposure limits, where applicable. The procedure is subject to no significant spectral interferences (see A.3), provided that suitable analytical isotopes are used. However, inadequate matrix-matching can adversely affect results.

Best Sellers From Chemical and Textile Sector

GSO 2528:2016
 
Gulf Technical Regulation
Cosmetic products – Technical Regulation of cosmetic and personal care products claims
BH GSO 2528:2017
GSO 2528:2016 
Bahraini Technical Regulation
Cosmetic products – Technical Regulation of cosmetic and personal care products claims
BH GSO 575:2017
GSO 575:2016 
Bahraini Standard
Facial tissue - paper
GSO 575:2016
 
Gulf Standard
Facial tissue - paper

Recently Published from Chemical and Textile Sector

GSO ISO 4437-3:2024
ISO 4437-3:2024 
Gulf Standard
Plastics piping systems for the supply of gaseous fuels — Polyethylene (PE) — Part 3: Fittings
GSO ISO 16075-1:2024
ISO 16075-1:2020 
Gulf Standard
Guidelines for treated wastewater use for irrigation projects — Part 1: The basis of a reuse project for irrigation
GSO ASTM F1700:2024
ASTM F1700:20 
Gulf Standard
Standard Specification for Solid Vinyl Floor Tile
GSO 2741:2024
 
Gulf Standard
Socks